DKI-N-02-St
Defibrillator DKI-N-02-St

PORTABLE DEFIBRILLATOR ДКІ-Н-02-СТ WITH BUILT-IN RECHARGEABLE BATTERY IS USED FOR ELECTRICAL CARDIOVERSION IN THE THERAPY OF ACUTE AND CHRONIC HEART BEAT ARRHYTHMIA THROUGH APPLICATION OF THE GURVICH-VENIN BIPHASIC ASYMMETRIC QUASI-SINUSOIDAL PULSE

  • the pulse ensures clinical effectiveness of 95-100 % at discharged energy of 200 J, which is twice less than energy discharge in defibrillators using other pulse wave forms (trapezoid, straight-lined). Such low energy allows minimizing myocardial electric injury, significantly increasing patient recovery chance, particularly after multiple defibrillations;
  • in the defibrillator DKI-N-02 St, state-of-the-art technology CCD (Current controlled defibrillation) is implemented to ensure stable current amplitude during the entire discharge, protecting the myocardium from its peak-pulse voltage.
TECHNICAL SPECIFICATIONS
Preset ECV (electrical cardioversion) energy doses «16 А, 45 J», «20 А, 65 J», «25 А, 90 J», «32 А, 140 J», «40 А, 200 J».
Values of pulse therapeutic parameters defining ECV dosage
  • form: biphasic asymmetric quasi-sinusoidal pulse;
  • pulse semi-wave length: 5±1 ms at the load of 25 to 100 Ohm;
  • current amplitude ration between the second and the first semi-waves: 0.5 ±0.1 at the load of 25 to 100 Ohm.
Compensation of interelectrode resistance automated compensation of interelectrode resistance impact upon the dosage-defining therapeutic parameters of the output biphasic pulse: current amplitude, and current ratio.
Discharge synchronization synchronization possibility of discharge synchronization from external synchronizer: ECG monitor, short-term anaesthesia apparatus etc.
Power supply from 220 V AC mains with automatic switch to power supply from the internal rechargeable battery in case of mains failure.
Time of energy accumulator charge to the maximum value
  • from 220 V AC mains: up to 6 s;
  • from the internal rechargeable battery: up to 9 s.
Self-test while discharge to the availability control unit built in the apparatus, as well as while discharge to the patient with message indication NORM/FAILURE TEST.
Indication
  • visual (light): operating from the mains or built-in rechargeable battery; contact availability in patient’s circuit, readiness to the discharge, norm/failure test;
  • audio: battery charging process, battery recharging requirement.
Rechargeable battery capacity automated, from the internal charging unit with visual (light) and audio indication of battery power status.
Number of maximum dose discharges while powering from completely charged battery 120.
Dimensions 385 х 342 х 140 mm.
Weight 5 kg.